FLO-RITE-TEMP® PRE-PIPED FOR THERMOSTATIC CONTROL OF RECIRCULATING HOT WATER SYSTEMS

Flo-Rite-Temp Pre-Piped for Thermostatic Control of Recirculating Hot Water Systems are factory-built water heating packaged solutions inclusive of a shell & tube heat exchanger fitted with an integral control valve for water heating and system temperature control.

The feed forward design instantly determines downstream hot water demand and directs cold water through the heat exchanger. Water is heated above legionella survival temperatures with constant pressure steam and then blended with a proportional amount of cold water to set point temperature.

Engineered specifically for recirculating hot water systems, the piping assembly includes a three-way thermostatic diverting valve.

Flo-Rite-Temp Pre-Piped for Thermostatic Control of Recirculating Hot Water Systems are available with single wall or double wall heat exchangers in 4 standard sizes each with a parallel/redundant option and can be customized to suit.

PRODUCT SPECIFICATIONS

Model Flow Capacity Hot Water Outlet Connection Size
FRT535R 35 gpm (132 lpm) 1-1/2″ (38 mm)
FRT665R 63 gpm (238 lpm) 2″ (51 mm)
FRT8120R 120 gpm (454 lpm) 3″ (76 mm)
FRT535DWR 35 gpm (132 lpm) 1-1/2″ (38 mm)
FRT665DWR 63 gpm (238 lpm) 2″ (51 mm)
FRT8120DWR 120 gpm (454 lpm) 3″ (76 mm)
FRT535PR 70 gpm (265 lpm) 2″ (51 mm)
FRT665PR 126 gpm (477 lpm) 3″ (76 mm)
FRT8120PR 240 gpm (908 lpm) 3″ (76 mm)
FRT535DWPR 70 gpm (265 lpm) 2″ (51 mm)
FRT665DWPR 126 gpm (477 lpm) 2″ (51 mm)
FRT8120DWPR 240 gpm (908 lpm) 3″ (76 mm)

RESOURCES

INSTALLATION AND MAINTENANCE

Flo-Rite-Temp® IOM

Flo-Rite-Temp® Accumulation Piping System

Flo-Rite-Temp® Clean In Place Instructions

Flo-Rite-Temp® Piping System

Flo-Rite-Temp® Radiant Heat or Closed Loop System Piping

Flo-Rite-Temp® Recirculation System Piping

Flo-Rite-Temp® Sizing Instructions

Flo-Rite-Temp® Start-Up Procedure

DRAWINGS – SINGLE WALL MODELS

Flo-Rite-Temp® FRT535R Revit File (RFA)

Flo-Rite-Temp® FRT665R Revit File (RFA)

Flo-Rite-Temp® FRT8120R Revit File (RFA)

Flo-Rite-Temp® FRT535DWR Revit File (RFA)

Flo-Rite-Temp® FRT665DWR Revit File (RFA)

Flo-Rite-Temp® FRT8120DWR Revit File (RFA)

Flo-Rite-Temp® FRT535PR Revit File (RFA)

Flo-Rite-Temp® FRT665PR Revit File (RFA)

Flo-Rite-Temp® FRT8120PR Revit File (RFA)

Flo-Rite-Temp® FRT535DWPR Revit File (RFA)

Flo-Rite-Temp® FRT8120DWPR Revit File (RFA)

DRAWINGS – DOUBLE WALL MODELS

Flo-Rite-Temp® FRT535R Specifications

Flo-Rite-Temp® FRT665R Specifications

Flo-Rite-Temp® FRT8120R Specifications

Flo-Rite-Temp® FRT535DWR Specifications

Flo-Rite-Temp® FRT665DWR Specifications

Flo-Rite-Temp® FRT8120DWR Specifications

Flo-Rite-Temp® FRT535PR Specifications

Flo-Rite-Temp® FRT665PR Specifications

Flo-Rite-Temp® FRT8120PR Specifications

Flo-Rite-Temp® FRT535DWPR Specifications

Flo-Rite-Temp® FRT8120DWPR Specifications

SPECIFICATIONS

Data Sheet – Flo-Rite-Temp Sizing Chart

Data Sheet – Flo-Rite-Temp Double Wall

Data Sheet – Flo-Rite-Temp Single Wall

Data Sheet – Flo-Rite-Temp® Model FRT535R

Data Sheet – Flo-Rite-Temp® Model FRT665R

Data Sheet – Flo-Rite-Temp® Model FRT8120R

Data Sheet – Flo-Rite-Temp® Model FRT535DWR

Data Sheet – Flo-Rite-Temp® Model FRT665DWR

Data Sheet – Flo-Rite-Temp® Model FRT8120DWR

Data Sheet – Flo-Rite-Temp® Model FRT535PR

Data Sheet – Flo-Rite-Temp® Model FRT665PR

Data Sheet – Flo-Rite-Temp® Model FRT8120PR

Data Sheet – Flo-Rite-Temp® Model FRT535DWPR

Data Sheet – Flo-Rite-Temp® Model FRT8120DWPR

DATA SHEETS

Storage Heater Replacement for Shower Use (Shanghai Gaoyang International Tobacco) Case Study

CASE STUDIES